Features/Fixes Added to this Release
- An issue was fixed that with particular configs where there was a random loss of audio/meters in the signal chain.
- An issue was fixed that if a config running in the BASIS is dragged to the Design Editor and one or more of the following parameters are the ONLY changes made, the config may not work properly when dragged back to the BASIS:
- Activating and deactivating cross-points in an existing Matrix Mixer Processor.
- Adding or removing filters in an existing Filter Processor.
- The Delay Max value in an existing Delay Processor.
- Changing the type or order of a filter in an existing Filter Processor.
- Changing the type or order of a crossover filter in an existing Crossover Processor.
- A bug was fixed that upon boot-up the BASIS LCD displays the error "CNET MAC Error" or "CNET System Dead".
- An issue was fixed in that while using third-party for control of BASIS (Crestron/AMX), the BASIS may reboot and cause the attached amps to go in and out of standby after multiple connect/disconnect messages.
- An issue was fixed that when working with configs in and out of the design editor, sometimes the parameters return to defaults.
- An issue was fixed that when creating a new venue the user cannot add or import archives.
- Another issue was fixed that when attempting to create a new venue while multiple static panels are open, an error states that the "ven.tmp" file cannot be found or that the file is corrupted and the new venue is not opened.
- An error was fixed that when attempting to create a new venue that already exists; Venue Manager shows no venue loaded and if you attempt to open the venue you had open previously and the venue never completes loading.
- In order to improve stability, the maximum number of channels in a single Automixer was reduced to 20.
- An issue was fixed that if long venue names were used the QSC Service Applet would crash.
- A fix was added for the paste parameters where the values would be correct in the Design Editor but would not be in the actual flash config.
- Added new macros with voicing's for the ILA, Wideline and their related subs.
IMPORTANT NOTES
SOFTWARE/HARDWARE FIREWALL SETTINGS: For communication between QSControl.net and any configured devices the firewall MUST be properly configured or disabled. To properly configure your firewall, unblock the following ports:
- UDP port 2501 for QSControl.net Venue Service or third party communications with CM16a products.
- TCP ports 4444 and 4445 for communications between QSControl.net Venue Service and BASIS Platform Products.
- TCP port 4446 for third party communications with BASIS Platform Products.
- TCP port 9000 for communication between a QSControl.net Venue Manager Remote Client and a local QSControl.net Venue Service communicating with BASIS Platform Products or CM16a products.
NOTE: Windows XP with Service Pack 2 includes a software firewall that is enabled by default.
WINDOWS AUTOMATIC UPDATE SETTINGS: If the system is used for real-time adjustments, monitoring or configuration of audio systems, then automatic updates (located in the Windows Control Panel) MUST be configured for manual updates or be disabled.
WINDOWS POWER MANAGEMENT SETTINGS: If the system is used for real-time adjustments, monitoring or configuration of audio systems, then we recommend all Windows Power Options (located in the Windows Control Panel) be disabled. Display, hard drive, system standby and hibernation settings should be set to “Never”. This avoids waiting for the system to “wake-up” if adjustment is needed after an elapsed period of time.